6-7
Maximum printable page length
available
The setting determined by these bits is informed to the
transmitting terminal in the pre-message protocol
exchange (in the DIS/NSF frames).
Bit 7
Bit 6
Setting
0
0
No limit
0
1
B4 (364 mm)
1
0
A4 (297 mm)
1
1
Not used
Communication Switch 02 (SP No. 1-104-003)
No
Function
Comments
0
G3 Burst error threshold
0: Low 1: High
If there are more consecutive error lines in the
received page than the threshold, the machine
will send a negative response. The Low and High
threshold values depend on the sub-scan
resolution, and are as follows.
100 dpi
6(L) 12(H)
200 dpi
12(L) 24(H)
300 dpi
18(L) 36(H)
400 dpi
24(L) 48(H)
1
Acceptable total error line ratio
0: 5% 1: 10%
If the error line ratio for a page exceeds the
acceptable ratio, RTN will be sent to the other
end.
2
Treatment of pages received with errors
during G3 reception
0: Deleted from memory without printing
1: Printed
0: Pages received with errors are not printed.
Bit Switches - 3
125
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...