MACHINE_ERR_06
Error
Code
Suggested Cause
Action
06
Timeout error on the node authentication
Adjust the value of SP5-741-001 to
prolong the timeout for node
authentication.
MACHINE_ERR_07
Error
Code
Suggested Cause
Action
07
Multiple destinations are set in the Client-side
Machine.
In the Client-side Machine, execute
SP5-801-021 to clear AICS memory
MACHINE_ERR_08
Error
Code
Suggested Cause
Action
08(1)
• A Client-side Machine connects to other
Client-side Machine.
• The Client-side Machine not registered in
the Remote Machine as destinations.
• Connect to the Remote Machine.
• Register the Client-side Machine to
the Remote Machine as a
destination.
08(2)
• A Remote Machine connects to other
Remote Machine.
• Wrong Remote Machine registered in
the Client-side Machine.
• Connect to the Client-side
Machine.
• Check what Remote Machine
registered in the Client-side
Machine.
3. Troubleshooting
72
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...