6805AB
CNG on time
20 ms
Factory setting: 500 ms
6805AC
CNG off time
20 ms
Factory setting: 3000 ms
6805AD
Number of CNG cycles required for
detection
-
The data is coded in the
same way as address
680533.
6805AE
Not used
-
Do not change the settings.
6805AF
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (high byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
6805B0
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (low byte)
6805B1
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (high byte)
Hz(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
6805B2
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (low byte)
6805B3
Detection time for 800 Hz AI short
protocol tone
20 ms
Factory setting: 360 ms
6805B4
PSTN: Tx level from the modem
-N – 3 dBm
SP2-103-002 (parameter
01).
6805B5
PSTN: 1100 Hz tone transmission level
- N 6805B4 - 0.5N 6805B5 –3.5 (dB)
See Note 7.
6805B6
PSTN: 2100 Hz tone transmission level
- N6805B4 - 0.5N 6805B6 –3 (dB)
See Note 7.
6805B7
PABX: Tx level from the modem
- dBm
6805B8
PABX: 1100 Hz tone transmission level - N 6805B7 - 0.5N 6805B8 (dB)
6805B9
PABX: 2100 Hz tone transmission level - N 6805B7 - 0.5N 6805B9 (dB)
NCU Parameters
171
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...