Code
Meaning
Suggested Cause/Action
0-77
The called terminal fell back to T.
30 mode, because it could not
detect a CJ in response to JM
(JM timeout).
• The calling terminal could not detect a JM due to
noise, etc.
• A network that has narrow bandwidth cannot
pass JM to the other end.
• Check the line connection and condition.
• Try receiving a call from another V.8/V.34 fax.
0-79
The called terminal detected CI
while waiting for a V.21 signal.
• Check for line noise or other line problems.
• If this error occurs, the called terminal falls back
to T.30 mode.
0-80
The line was disconnected due to
a timeout in V.34 phase 2 – line
probing.
• The guard timer expired while starting these
phases. Serious noise, narrow bandwidth, or
low signal level can cause these errors.
If these errors happen at the transmitting terminal:
• Try making a call at a later time.
• Try using V.17 or a slower modem using
dedicated tx parameters.
• Try increasing the tx level.
• Try adjusting the tx cable equalizer setting.
If these errors happen at the receiving terminal:
• Try adjusting the rx cable equalizer setting.
• Try increasing the tx level.
• Try using V.17 or a slower modem if the same
error is frequent when receiving from multiple
senders.
0-81
The line was disconnected due to
a timeout in V.34 phase 3 –
equalizer training.
0-82
The line was disconnected due to
a timeout in the V.34 phase 4 –
control channel start-up.
0-83
The line was disconnected due to
a timeout in the V.34 control
channel restart sequence.
0-84
The line was disconnected due to
abnormal signaling in V.34 phase
4 – control channel start-up.
• The signal did not stop within 10 s.
• Turn off the main power switch, then turn it back
on.
• If the same error is frequent, replace the FCU.
0-85
The line was disconnected due to
abnormal signaling in V.34
control channel restart.
• The signal did not stop within 10 s.
• Turn off the main power switch, then turn it back
on.
• If the same error is frequent, replace the FCU.
Error Codes
55
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...