Bit Switches - 1
• Do not adjust a bit switch or use a setting that is described as "Not used", as this may cause the
machine to malfunction or to operate in a manner that is not accepted by local regulations. Such
bits are for use only in other areas, such as Japan.
Default settings for bit switches are not listed in this manual. Refer to the System Parameter List printed by
the machine.
System Switches
System Switch 00 (SP No. 1-101-001)
No
Function
Comments
0
Dedicated transmission parameter
programming
0: Disabled
1: Enabled
Set this bit to 1 before changing any dedicated
transmission parameters.
This setting is automatically reset to "0" after turning
off and on.
1
Not used
Do not change this setting.
2
Technical data printout on the
Journal
0: Disabled
1: Enabled
1: Instead of the personal name, the following data
are listed on the Journal for each G3 communication.