10 February 2005
SCANNER UNIT
3-7
Replacement
Adjustment
16. Disconnect the connector [A].
17. Remove the paper length sensor [B]
(
x 1).
18. Remove the scanner lamp cable (
[C] with a screw).
19. Remove the cable guide [D].
Reassembling
•
When you install the scanner lamp,
make sure that the binding [E] is set as
shown. Also, make sure that the cable
that has a black tube is installed on the
cable guide as shown [F].
•
The cable must not be loose. Move the
clamp [G] to adjust the tension in the
cable.
B156R102.WMF
NG
OK
B156R104.WMF
[A]
[B]
[C]
[D]
[F]
[G]
[E]