10 February, 2005
SERVICE PROGRAM MODE
5-29
Service
Tables
4
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
800
3
B
Adjusts the blue density when scanning with the ARDF
[–20
∼
20 /
0
/ 1 %/step]
Level Adjustment: R
885
Adjusts the ADC reference voltage. Details are in
Replacement and Adjustment.
[ –128 ~ 127 /
49
/ 1 /step]
Level Adjustment: G
886
Adjusts the ADC reference voltage.
[ –128 ~ 127 /
17
/ 1 /step]
Level Adjustment: B
887
Adjusts the ADC reference voltage.
[ –128 ~ 127 /
29
/ 1 /step]
ACC Data Display
1
R DATA 1
2
G DATA 1
3
B DATA 1
4
R DATA 2
5
G DATA 2
902
6
B DATA 2
Displays ACC data.
[0
∼
255 /
0
/ 1 /step]
Dither selection
905*
1 Dither
selection
[0
∼
255 /
0
/ 1 /step]
DFU
Binary Threshold
906*
1
Binary Threshold
Specifies the black/white threshold for binary image
processing.
[0
∼
255 /
128
/ 1 /step]
Lower values increase the proportion of black in the
image.
VPU Test Pattern Selection
1
select any test pattern:
R
2
select any test pattern:
G
907
3
select any test pattern:
B
[0
∼
4 /
0
/ 1 /step]
•
0: CCD
•
1: Black
•
2: White
•
3: 15-grade gray scale
•
4: Vertical line
Manual Gamma Adjustment
918
Please refer to section 3.13.2
Picture Element Correction
1 R:
Left
2 R:
Right
3 B:
Left
932*
4 B:
Right
Corrects the left or right side alignment of the red or blue
filter on the CCD.
[0
∼
9 /
5
/ 1 /step]
Содержание TH-C1b