SERVICE PROGRAM MODE
10 February, 2005
5-66
7
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
Time Cnter Disp (Time Counter Display)
925
1
Time Cnter Disp
Displays the current counter of the charge corona unit
cleaning interval. (Number of counts since the last
cleaning)
SP2-801 specifies the charge corona unit cleaning
interval.
Chgr Cln Cnt Rst (Charger Cleaner Counter Reset)
926
1
Chgr Cln Cnt Rst
Resets the charge wire cleaner counter (SP7-924).
Time Cnter Clr (Timer Counter Clear)
927
1
Time Cnter Clr
Clears the counter of the charge corona unit cleaning
interval.
SP7-927 clears the counter displayed by SP7-925, but
does not clear the value specified with SP2-801.
PREV PM Cnt Clr (Previous PM Counter Clear)
928
1
PREV PM Cnt Clr
Clears the previous PM counter (SP7-906).
Replace Cnter Clr (Replace Counter Clear)
929
1
Replace Cnter Clr
Clears the replace counter.
Engine Status Display
DFU
1 Status
1
2 Status
2
3 Status
3
4 Status
4
5 Status
5
6 Status
6
7 Status
7
8 Status
8
9 Status
9
10 Status
10
11 Status
11
12 Status
12
13 Status
13
14 Status
14
15 Status
15
16 Status
16
931
17 Status
17
These SPs are used for previous models.
Coverage Cler (Coverage Clear)
1
Average
Clears the average coverage.
This SP clears the following SPs:
•
SP8-831-1 to 4
•
SP8-841-1 to 4
2
Toner
Clears the consumed toner bottle number.
This SP clears the following SP:
•
SP8-781-1 to 4
934
3
S: PREV Toner
Clears the number of prints copied or printed with last
toner bottle.
This SP clears the following SPs:
•
SP8-891-1 to4
•
SP8-901-1 to 4
•
SP8-911-1 to 4