The counter for “development counts” counts up as shown in the table.
Black & White
Color
A4 (LT) LEF (or smaller)
1 count
4 counts
Others
2 counts
8 counts
NOTE:
1) The counter always increases as shown in the table. These values are
not adjustable.
2) To change the cleaning interval, use SP2-801 (
☛
5.1.2).
Quenching
[A]: Quenching lamp
[B]: Charge corona unit
[C]: OPC belt
(
☛
!
Photocopying Processes – Quenching)