10 February, 2005
SERVICE PROGRAM MODE
5-35
Service
Tables
5
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
1
Paper Supply Alarm
Turns the supply alarm on or off.
[0
∼
1 /
0
/ 1 /step]
•
0: Off
•
1: On
This alarm occurs when one of the limits in SPs 5507-
128 to 172 is reached.
2
Staple Supply Alarm
Turns the supply alarm on or off.
[0
∼
1 /
0
/ 1 /step]
•
0: Off
•
1: On
This alarm occurs when every 1000 staples are used.
3
Toner Supply Alarm
Turns the supply alarm on or off.
[0
∼
1 /
0
/ 1 /step]
•
0: Off
•
1: On
This alarm occurs when toner near end occurs.
128 Interval:
Others
132 Interval:
A3
133 Interval:
A4
134 Interval:
A5
141 Interval:
B4
142 Interval:
B5
160 Interval:
DLT
164 Interval:
LG
166 Interval:
LT
172 Interval:
HLT
The machine issues the control call when the number of
paper sheets reaches the specified value.
[ 250
∼
10000 /
1000
/ 1 sheet/step]
CC Call Used with RSS.
1
Jam Remains
Enables/disables alarms for unremoved jams.
[0
∼
1 /
1
/ 1 /step]
•
0: Disabled
•
1: Enabled
2
Continuous Jams
Enables/disables alarms for consecutive jams.
[0
∼
1 /
1
/ 1 /step]
•
0: Disabled
•
1: Enabled
508
3
Continuous Door Open Enables/disables alarms when a cover remains open
continuously.
[0
∼
1 /
1
/ 1 /step]
•
0: Disabled
•
1: Enabled