10 February 2005
ANTI-CONDENSATION HEATER
1-67
Ins
ta
lla
tion
7. Remove the rear scale [A] (
!
x 3), left scale [B] (
!
x 2), and exposure glass
[C].
NOTE:
When installing the exposure glass, make sure that the mark [D] is
positioned at the rear left corner, as shown.
8. Install the anti-condensation heater [E] (
!
x 2,
"
x 1).
9. Reinstall the exposure glass and the scales.