5.13 ANTI-CONDENSATION HEATER
To prevent condensation in the optics unit, a 40 W anti-condensation heater
[A] is installed at the bottom of the lens unit.
The anti-condensation heater is controlled by a thermoswitch [B] (On at
17°C, Off at 25°C) under the following conditions:
1. The main switch is off.
2. The main switch is on, fusing lamp off in stand-by mode.
3. Machine off condition in weekly timer mode.
The anti-condensation heater has a thermofuse (169°C).
5.14 OPTICS COOLING FAN
The light intensity will be decreased if the fluorescent lamp temperature
becomes too high. The optics cooling fan [A] blows in cool air from outside
through an air filter [B]. Air from the fan also passes through the 6th mirror slit
[C] to the drum area. This prevents the optics area from being contaminated
by scattered toner in the drum unit.
[B]
[A]
A171D566.img
[B]
[A]
[C]
A171D5747.img
31 July 1995
OPTICS
2-37