SC542 - Low Fusing Temperature
Definition:
The main PCB detects a low fusing temperature (fusing lower limit
temperature : 159°C/–17 169°C/–27) for more than 10 minutes.
NOTE: The Service Call message will be displayed at the first detection.
The main relay will be opened in this condition.
The fusing lower limit temperature can be changed by user tools
and service program mode.
Points to check
•
Fusing lamp
•
Fusing lamp control SSR
•
Main Relays (RA101 and 102)
•
Fusing thermistor
•
Interface PCB
SC543 - Fusing overheat
Definition:
The main PCB detects an extremely low resistance (< 500
Ω
/220°C) of the
fusing thermistor for more than 3 seconds.
NOTE: The service call message will be displayed at the first detection.
The main relays will be opened in this condition.
Points to check:
•
Fusing lamp control SSR
•
Fusing thermistor
•
Fusing lamp
•
Interface PCB
SC547 - Fusing Thermofuse Open
Definition:
Main PCB detects the fusing thermofuse open signal from the dc drive PCB
for more than 3 seconds.
NOTE: The service call message will be displayed at the first detection.
The main relays will be opened in this condition.
Points to check:
•
Thermofuse
•
DC drive PCB
SYSTEM ERROR AND SERVICE CALL CONDITIONS
31 July 1995
6-20
Содержание FT8680
Страница 3: ...SECTION 1 OVERALL MACHINE INFORMATION ...
Страница 8: ...MEMO 31 July 1995 SPECIFICATIONS 1 5 ...
Страница 23: ...6 5 IMAGE OVERLAY MODE 2ND SIDE A171V505 wmf PAPER PATH 31 July 1995 1 20 ...
Страница 24: ...SECTION 2 DETAILED SECTION DESCRIPTIONS ...
Страница 133: ...Timing Chart 1 Stack 2 Paper Feed A171D551 wmf A171D552 wmf 31 July 1995 DUPLEX 2 109 ...
Страница 159: ...SECTION 3 INSTALLATION ...
Страница 177: ...SECTION 4 SERVICE TABLES ...
Страница 229: ...SECTION 5 REPLACEMENT AND ADJUSTMENT ...
Страница 362: ...SECTION 6 TROUBLESHOOTING ...