SC353 - Vsg Abnormal
Definition:
The main PCB detects a low Vsg value (V) five times in a row.
NOTE: Toner supply shifts to the 7% fixed supply mode. If the Vsg
returns to normal level, standard detect supply resumes. No
service call condition is displayed.
Points to check:
•
ID sensor
•
Erase lamp
•
Drum
•
Developer
SC354 - Vsg Adjustment Error
Definition:
During process control data initialization, the main PCB cannot adjust the ID
sensor output for the Vsg to the standard voltage (4.0
±
0.2 V).
NOTE: After resetting the system error condition, the toner supply shifts
to 7% fixed supply mode until the next adjustment.
Points to check:
•
ID sensor
•
Drum
•
Main PCB (ID sensor control circuit)
SC390 - Development Motor Overload
Definition:
The motor control PCB cannot maintain the motor speed within the
specification for more than 1.5 seconds. The motor control PCB detects a
large current value (3 A) at the development motor for more than 2 seconds.
Points to check:
•
Mechanical interference with the development motor
•
Development motor and encoder
•
Motor control PCB
•
DC motor drive PCB (Fuse: F3)
31 July 1995
SYSTEM ERROR AND SERVICE CALL CONDITIONS
6-11
Содержание FT8680
Страница 3: ...SECTION 1 OVERALL MACHINE INFORMATION ...
Страница 8: ...MEMO 31 July 1995 SPECIFICATIONS 1 5 ...
Страница 23: ...6 5 IMAGE OVERLAY MODE 2ND SIDE A171V505 wmf PAPER PATH 31 July 1995 1 20 ...
Страница 24: ...SECTION 2 DETAILED SECTION DESCRIPTIONS ...
Страница 133: ...Timing Chart 1 Stack 2 Paper Feed A171D551 wmf A171D552 wmf 31 July 1995 DUPLEX 2 109 ...
Страница 159: ...SECTION 3 INSTALLATION ...
Страница 177: ...SECTION 4 SERVICE TABLES ...
Страница 229: ...SECTION 5 REPLACEMENT AND ADJUSTMENT ...
Страница 362: ...SECTION 6 TROUBLESHOOTING ...