10
SP Special Features – 2 (PAGE 4)
Item
Function
Setting
Default
Process Control
OFF Mode
Disables process control.
Enable
Disable
Process Control
Auto Start Mode
To maintain optimum copy quality,
process control automatically works
at 12 o’clock midnight even if the
main switch is not turned off.
No
Yes
Rotates the main motor and
development motor for
approximately 5 minutes after warm
up.
No
Yes
Toner Density
Selection
Selects a voltage shift for ID sensor
bias.
–60 V
0 V
+60 V
+120 V
Toner Supply
Amount
Selects how much toner is supplied
in detect mode.
ID Selection in
ADS Mode
Selects the voltage shift for the
development bias in ADS Mode.
+60 V
0 V
–60 V
–120 V
RESET
SET
RESET
SET
SET
HIGH
30%
NORMAL
LOW
NORMAL
HIGH
VHIGH
LOW
NORMAL
HIGH
VHIGH
RESET
RESET
SET
RESET
A171M537.img
SERVICE PROGRAM MODE
1 July 1995
4-30