
SC106 - Low FL Temperature
Definition:
During stand-by, the main PCB detects a high resistance (> 5.6k: 10°C) of
the FL thermistor for more than 15 minutes.
NOTE: 1. No detection in copy mode.
2. 24 V (VP) and 38 V (VFL) will be cut by the relays on the dc
drive PCB in this SC condition.
Points to check:
•
Exposure lamp heater
•
FL thermistor
•
FL temperature fuse
•
DC drive PCB
•
Main PCB (CN102-B20)
SC108 - V
L
Correction Error
Definition:
Target V
L
value cannot be achieved within the exposure lamp output control
range during the process control data initialization.
NOTE: After resetting the system error condition, V
L
correction will be
tried again. Even if the second execution fails, no service call
condition is displayed and the copier uses previous reference
data until its next initialization.
Points to check:
•
Exposure lamp
•
Drum potential sensor
•
Drum
•
Optics dirtiness
•
V
L
sensor pattern
•
Erase lamp
SYSTEM ERROR AND SERVICE CALL CONDITIONS
31 July 1995
6-4
Содержание FT8680
Страница 3: ...SECTION 1 OVERALL MACHINE INFORMATION ...
Страница 8: ...MEMO 31 July 1995 SPECIFICATIONS 1 5 ...
Страница 23: ...6 5 IMAGE OVERLAY MODE 2ND SIDE A171V505 wmf PAPER PATH 31 July 1995 1 20 ...
Страница 24: ...SECTION 2 DETAILED SECTION DESCRIPTIONS ...
Страница 133: ...Timing Chart 1 Stack 2 Paper Feed A171D551 wmf A171D552 wmf 31 July 1995 DUPLEX 2 109 ...
Страница 159: ...SECTION 3 INSTALLATION ...
Страница 177: ...SECTION 4 SERVICE TABLES ...
Страница 229: ...SECTION 5 REPLACEMENT AND ADJUSTMENT ...
Страница 362: ...SECTION 6 TROUBLESHOOTING ...