SC404 - Transfer Corona Cleaner Failure
Definition:
The main PCB detects a large current for the transfer corona wire cleaner
motor (mechanism lock) for more than 3 seconds when the cleaner is
activated.
NOTE: The cleaner moves back to its home position when the error
condition is reset.
Points to check:
•
Mechanical interference with the transfer corona wire cleaner
•
Wire cleaner motor
•
Main PCB (motor drive circuit)
SC410 - Separation Corona Current Adjustment Error
Definition:
When process control data initialization is selected in the SP mode, the main
PCB cannot adjust the separation corona current to its target value.
NOTE: After resetting the system error condition, the adjustment will be
tried again. Even if the second execution fails, no service call
condition is displayed and the copier uses previous reference
data until its next initialization.
Points to check:
•
Separation Corona unit
•
Separation Corona power pack
•
Drum
•
Drum current detection PCB
SC411 - Separation Corona Leakage
Definition:
The separation corona power pack detects the separation corona leakage
and sends the leak signal to the main PCB for more than 3 seconds.
NOTE: DC power, 24 V (VP) and 38 V (VFL), will be cut at the same
time.
Points to check:
•
Separation corona unit
•
Separation power pack
•
Interface PCB
SYSTEM ERROR AND SERVICE CALL CONDITIONS
31 July 1995
6-14
Содержание FT8680
Страница 3: ...SECTION 1 OVERALL MACHINE INFORMATION ...
Страница 8: ...MEMO 31 July 1995 SPECIFICATIONS 1 5 ...
Страница 23: ...6 5 IMAGE OVERLAY MODE 2ND SIDE A171V505 wmf PAPER PATH 31 July 1995 1 20 ...
Страница 24: ...SECTION 2 DETAILED SECTION DESCRIPTIONS ...
Страница 133: ...Timing Chart 1 Stack 2 Paper Feed A171D551 wmf A171D552 wmf 31 July 1995 DUPLEX 2 109 ...
Страница 159: ...SECTION 3 INSTALLATION ...
Страница 177: ...SECTION 4 SERVICE TABLES ...
Страница 229: ...SECTION 5 REPLACEMENT AND ADJUSTMENT ...
Страница 362: ...SECTION 6 TROUBLESHOOTING ...