NCU PARAMETERS
21 May, 1999
4-42
4.3 NCU
PARAMETERS
The following tables give the RAM addresses and the parameter calculation units
that the machine uses for ringing signal detection and automatic dialing. The
factory settings for each country are also given. The RAM read/write (Function 06)
must change most of these, but NCU Parameter programming (Function 08) can
change some others; if Function 08 is in use, the Remarks column indicates it. The
RAM is in hex code unless (BCD) is included in the Unit column.
Address
Function
Unit
Remarks
81E500
Country code for NCU parameters
Use the Hex value to program the
country code directly into this address,
or use the decimal value to program it
using Function 08 (parameter C.C.).
Country
Decimal
Hex
France
00
00
Germany
01
01
UK
02
02
Italy
03
03
Austria
04
04
Belgium
05
05
Denmark
06
06
Finland
07
07
Ireland
08
08
Norway
09
09
Sweden
10
0A
Switzerland
11
0B
Portugal
12
0C
Holland
13
0D
Spain
14
0E
Israel
15
0F
USA
17
11
Asia
18
12
Hong Kong
20
14
South Africa
21
15
Australia
22
16
New Zealand
23
17
Singapore
24
18
Malaysia
25
19
Turkey
32
20
Greek
33
21
81E501
Line current detection time
20 ms
Line current is not detected
81E502
Line current wait time
if 81E501 contains FF.
81E503
Line current drop detect time