21 May, 1999
BIT SWITCHES
4-21
Service
Tables
3
Continuous polling reception
0: Disabled 1: Enabled
This feature allows a series of stations to be
polled in a continuous cycle.
4
Dialing on the ten-key pad
when the handset is off-hook
0: Disabled 1: Enabled
1: The user can dial on the ten-key pad when
the handset is off-hook.
This switch cannot be used in the I-Schmidt3.
5
On-hook dial
0: Disabled 1: Enabled
0: On-hook dial is disabled.
This switch cannot be used in the I-Schmidt3.
6
Line used for G3 transmission
0: PSTN
1: ISDN
If an ISDN kit has been installed, this bit
determines whether G3 transmissions go out
over the PSTN or the ISDN.
7
Line used when the machine
falls back to G3 from G4 if the
other end is not a G4 machine
0: PSTN
1: ISDN
This bit switch has no effect if Communication
Switch 07 bit 0 is set to 0.
System Switch 0B
No
FUNCTION
COMMENTS
0
1
Automatic reset timer
Bit 1 Bit 0 Timer setting
0 0 1 minute
0 1 3 minutes
1 0 5 minutes
1 1 No limit
(1, 1): Automatic reset is disabled.
(Other): The machine returns to standby mode
when the timer expires after the last operation.
2
3
Power Saver mode timer
Bit 3 Bit 2 Time Limit
0 0 1 minute
0 1 3 minutes
1 0 5 minutes
1 1 No limit
(1, 1): Automatic Power Saver mode is
disabled.
(Other): The machine goes into Power Saver
mode when the timer expires after the last
operation.
Cross-reference
Power Saver modes: Section 2.3.1
4-6
Not used
Do not change these settings.
7
Keys to be pressed to exit the
energy saver mode
0: Only the energy saver key
1: Any key
1: Any key can be pressed to exit the energy
save mode