21 May, 1999
SYSTEM FEATURES
2-37
Detailed
Descriptions
Reduction Disabled
If bit 0 of printer switch 03 is at 0 (Disabled), the data will not be reduced. In
addition, if the incoming page is up to x mm longer than the copy paper, the excess
portion will not print. The setting of bits 4 to 7 of printer switch 03 determine the
value of x, somewhere between 0 to 15 mm.
Hex value
Value of X
0
0
0
1
and so on until
F
15
Messages more than x mm longer than the copy paper will print out on two pages
in accordance with the setting of bit 1 of printer switch 00, as explained earlier.
2.3.5 MEMORY RECEPTION CONDITIONS
User parameter switch 05 bit 1 allows the user to select how to treat an incoming
message that is without RTI or CSI.
User parameter switch 05 Bit-1:
Memory reception if no RTI or CSI received 0: Possible, 1: Impossible
If 0 is selected, the machine receives all messages regardless of RTI and CSI.
If 1 is selected (this is the default setting), the user parameter setting works in
combination with the following bit switch.
System Bit Switch 11 Bit 6:
Conditions for memory reception if no RTI or CSI is received.
0: Impossible; memory reception is available only after receiving the RTI or CSI.
1: Memory reception is possible if there is no mechanical (printer)
error.
The default setting is 1. The default setting means that if the printer is working, it
will receive all messages. However, when there is a mechanical error in the printer,
the machine rejects such a message because no trace of the sender will be stored
in the machine.