21 May, 1999
INSTALLALING OPTIONAL UNITS
3-3
Installation
3.3.2 COUNTER
Installation Procedure
1. Remove the top cover [A] (4 screws, 1 screw
with spring plate).
NOTE: Be careful not to damage the bottom
part of the top cover with the scanner
cover after removing the spring plate.
2. This step is required only for the H548
models.
Remove the G4 unit cover [B] (1 screw) and the
ISDN board [C] (2 screws).
3. Remove the G4 cover [D] (1 screw) and
the FCU shield plate [E] (1 screw).
Connect the counter harness [F] to the
FCU [G] (CN48).
Then secure the harness through
harness holders as shown.
4. Attach the harness clamp [H] to the
NCU bracket and secure the counter
harness. Pass the counter harness
underneath the PSU and NCU
harnesses [I] as shown.
Then replace the FCU shield plate and
the G4 cover which were removed in
step 3.
H547R514.WMF
H547I508.WMF
H547I502.WMF
[D]
[E]
[F]
[H]
[G]
[I]
[B]
[C]
[A]