21 May, 1999
BIT SWITCHES
4-31
Service
Tables
3
Hang-up decision after
receiving a negative code
(RTN or PIN) during G3
immediate transmission
0: No hang-up
1: Hang-up
0: Sends the next page even if RTN or PIN is
received.
1: The machine will send DCN and hang up if it
receives RTN or PIN.
This bit is ignored for memory transmissions or if
ECM is being used.
4-7
Not used
Do not change these settings.
Communication Switch 03
No
FUNCTION
COMMENTS
0
to
7
Maximum number of page
retransmission in a G3
memory transmission
00 - FF (Hex) times.
This bit is ignored if ECM is in use.
Communication Switch 04 - Not used (do not change any of these settings)
Communication Switch 05 - Not used (do not change any of these settings)
Communication Switch 06
No
FUNCTION
COMMENTS
0
Dialing requirements:
Germany
0: Disabled 1: Enabled
1
Dialing requirements: Austria
0: Disabled 1: Enabled
2
Dialing requirements: Norway
0: Disabled 1: Enabled
3
Dialing requirements:
Denmark
0: Disabled 1: Enabled
4
Dialing requirements: France
0: Disabled 1: Enabled
5
Dialing requirements:
Switzerland
0: Disabled 1: Enabled
6
Dialing requirements:
USA
0: Disabled 1: Enabled
This function automatically sets these switches
to the required settings for each country after
selecting a country code (System Switch 0F).
7
Not used
Do not change these settings.