NCU PARAMETERS
21 May, 1999
4-44
Address
Function
Unit
Remarks
81E51B
PABX dial tone detection time
81E51C
PABX dial tone reset time (low)
81E51D
PABX dial tone reset time (high)
81E51E
PABX dial tone continuous tone
time
81E51F
PABX dial tone permissible drop
time
If 81E51B contains FF, the
machine pauses for the
pause time (81E520 /
81E521).
81E520
PABX wait interval (high)
81E521
PABX wait interval (low)
20 ms
81E522
PABX ring-back tone detection time
20 ms
81E523
PABX ring-back tone off detection
time
20 ms
If both addresses contain
FF(H), tone detection is
disabled.
81E524
PABX detection time for the silent
period after ring-back tone detected
(low)
20 ms
If both addresses contain
FF(H), tone detection is
disabled.
81E525
PABX detection time for the silent
period after ring-back tone detected
(high)
20 ms
If both addresses contain
FF(H), tone detection is
disabled.
81E526
PABX busy tone frequency upper
(high byte)
81E527
PABX busy tone frequency lower
(low byte)
Hz
(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
81E528
PABX busy tone frequency lower
(high byte)
81E529
PABX busy tone frequency lower
(low byte)
Hz
(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
81E52A
Busy tone ON time: range 1
20 ms
81E52B
Busy tone OFF time: range 1
81E52C
Busy tone ON time: range 2
81E52D
Busy tone OFF time: range 2
81E52E
Busy tone ON time: range 3
81E52F
Busy tone OFF time: range 3
81E530
Busy tone ON time: range 4
81E531
Busy tone OFF time: range 4
81E532
Busy tone-continuous tone
detection time