![Rice Lake iQube 920i Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/rice-lake/iqube-920i/iqube-920i_installation-manual_1453911009.webp)
6
iQUBE
Installation Manual
DIP switches on the core module of each
iQUBE
must
be set to indicate whether the unit is a primary or
secondary, the communication protocol and port used,
and the secondary address.
•
For the primary unit, DIP switches 1–3 must
all be set OFF. Set switches 5 and 6 based on
the protocol (RS-232 or RS-485) and port (J7
or J6) used to communicate with the host
device.
•
For secondary units, DIP switch 5 must be set
ON; use switches 1–3 to set the secondary
address as shown in Table 2-5.
See Section 2.9 on page 10 for more information
about the core module DIP switches.
Figure 2-3. 920i Wiring
DIP
Switch
Primary Unit
Secondary Unit
1–3
OFF, OFF, OFF
ON, OFF, OFF = SECONDARY1
OFF, ON, OFF = SECONDARY2
ON, ON, OFF = SECONDARY3
5
RS-232 = OFF
RS-485 = ON
ON
6
OFF = J7
ON = J6
iQUBE
Port
Table 2-5. Core Module Communications DIP Switches
J7
GND
S
HLD
YB
Z/TXD
A
/RXD
1
PRIMARY
iQUBE UNIT
iQUBE UNIT
TXD
RXD
GND
RS-232
J7
GND
S
HLD
YB
Z/TXD
A/RXD
1
PRIMARY
iQUBE UNIT
iQUBE UNIT
A R
S
-485 TXD +
A R
S
-485 TXD -
A R
S
-485 RXD +
RS-485
A R
S
-485 RXD -
120
Ω
120
Ω
RS-232 to
Host PC (920i)
RS-485 to
920i Serial
Option Board