![Rice Lake iQube 920i Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/rice-lake/iqube-920i/iqube-920i_installation-manual_1453911039.webp)
36
iQUBE
Installation Manual
6.4
Diagnostic Setup
Parameters associated with each of the
iQUBE
’s
diagnostic tests can be set using the
920i
menus,
iRev
,
or
Revolution III
. See Section 3.4.2 on page 25 for
descriptions of the
iQUBE
diagnostic parameters for
the
920i
.
Figure 6-5.
Revolution III
Diagnostic Setup Display
6.4.1
Configuring the 920i Diagnostics Softkey
When using the
iQUBE
with the
920i
indicator, a
Diagnostics
softkey can be configured to display
diagnostic information when in weigh mode. Use the
FEATURE menu, SOFTKEYS submenu, to select the
Diagnostics softkey (see Figure 6-6).
Figure 6-6. Selecting Diagnostics Softkey
6.4.2
920i Diagnostic Display
Figure 6-7 shows an example of a
920i
display of
iQUBE
diagnostic information. Information shown
includes the following:
•
Cell name
•
Cell deadload value (mV)
•
Current individual cell and total values (mV)
•
Number of weighments
•
Cell status for highlighted cell. Use the
indicator navigation keys to select cells.
NOTE:
Displayed deadload and current values are raw
millivolt values. All diagnostic measurements use
corrected mV values:
corrected_value = current_value – deadload_value
Figure 6-7.
920i
Diagnostic Display
The
920i
diagnostic display can be shown by pressing
the
Diagnostic
softkey (if configured).
In setup mode, diagnostic information can be shown
by going to the VERS menu., pressing the
Contact
softkey, then the
Next
softkey.
Access through the VERS menu also displays
softkeys for
Clear Diagnostics
and, if cell emulation is
enabled,
Cell Emulation
. If cell emulation is set to
AUTO2 or MANUAL2 (see page 27), a
S
napshot
softkey is also shown.
6.5
Error Messages
Table 6-3 shows the alert system status messages
generated by the
iQUBE
.
Error messages are displayed on the indicator and can
be used by print formats and
iRite
user programs.
S
cale
Number
S
tatus Message
Cell Error
Messages
Cell ID
Scale
x
System boundary error:
Weighing error:
Master error:
Error 1 Cell
Error 2 Cell
Error 3 Cell
A
n,
B
n,
C
n
,
D
n
Table 6-3. Alert Error Message Format