920i Indicator Configuration
23
S
ERIAL Menu (
iQUBE
S
ubmenu)
Parameter
Choices
Description
CONFIG
8/0/0/0
8/4/0/0
8/4/4/0
8/8/0/0
4/0/0/0
4/4/0/0
4/4/4/0
4/4/4/4
4/8/0/0
Specifies the
iQUBE
system configuration.
The first value (8 or 4) designates the number of channels on the
iQUBE
primary board;
the remaining three values represent attached secondary units, if any, and the number of
channels on each secondary board.
NOTE: The
iQUBE
allocates either 4 or 8 channels per board. Total channels cannot
exceed 16; an 8-channel board cannot be defined as a 4-channel board.
CELLS
CELLA1–CELLA8
List of cells for
CONFIG type
Depending on the value specified for CONFIG, load cells are listed using default names
with the format CELL
xy
, where
x
is the board identifier (A is the primary unit; B, C, and D
are secondary units), and
y
is a designation (1–4 or 1–8, depending on the number of
channels supported by the board), for the individual load cell.
Subparameters allow load cell ID, capacity, sensitivity, and serial number to be specified.
See descriptions under
Level 4
S
ubmenus
.
SECTION
PAIRED
CIRCULAR
Specifies whether the load cells defined for the section are referenced to each other as
pairs or in a circular relationship. Sections with an odd number of cells must specify
CIRCULAR. Full diagnostic capability requires PAIRED section configuration.
See Section 2.3 on page 3 for information about load cell build order.
PLATFM
List of cells and
platforms
Use the Add softkey to associate load cells with platforms.
SYSTEM
List of platforms
and systems
Use the Add softkey to associate platforms with an
iQUBE
system. A system can
consist of 1–4 platforms.
ALGOUT
SOURCE
FULLSC
Specifies the source system and full scale value for an
iQUBE
analog output. See
descriptions under
Level 4
S
ubmenus
.
DIGIO
BIT 1 – BIT 8
For
iQUBE
models with digital I/O, specifies the function of each of the digital I/O bits.
See the
920i
Installation Manual
, PN 67887, for information about digital I/O functions.
IQDIAG
ZEROREF
CELLBAL
LDRIFT
PKtoPK
CELLEMU
MOTBAND
See
Level 4
S
ubmenus,
Figure 3-3 on page 25
,
and Table 3-2 on page 26.
TESTCOM
VALIDAT
Select VALIDAT to run a communication validation test for one or more attached
iQUBE
s. The validation test returns the serial numbers of all attached
iQUBE
s.
PORTTYPE
RS232
RS485
Specifies the port designation.
Level 4
S
ubmenus
ID
load_cell_ID
Specifies the load cell ID. Press
enter
to exit this parameter.
CAPCTY
75000
capacity
Enter the rated load cell capacity.
SENS
3.000000
sensitivity (mV/V)
Enter the actual or nominal load cell millivolt/volt sensitivity.
SRLNUM
serial_number
Optional. Enter the load cell serial number.
Table 3-1. Serial Menu Parameters,
iQUBE
Submenu