2.12 Installing Tap and Run Connectors for 920i Power
iQUBE
installations that are remotely powered by the
920i
indicator, and those that use the
920i
internal
fiber-optic module, require tap and run connectors to
draw power from the
920i
power supply (see Figures
2-13 and 2-14).
To install tap and run connectors in the
920i
indicator,
do the following:
1. Place red (+6V) wire from
920i
power supply
inside the run channel of the tap and run
connector. The cable tie used to secure the
power supply wires may need to be cut to allow
sufficient slack in the wires.
2. Close side cover of connector until latched.
3. Insert tap wire (+6V supply to
iQUBE
) into
connector. Use inspection port to check wire
position.
4. Use crimping tool to drive u-contact down flush
with top of connector. Close hinged top cover
until latched.
5. Repeat procedure for green (GND) wire tap and
run connector.
6. Use cable ties to secure power supply wires
inside the enclosure.
Figure 2-13.
920i
Tap and Run Connector Installation
Figure 2-14.
920i
Tap and Run Connector Installation for Internal Fiber-Optic Interface
See Section 2.14.4 on page 16 for more information about installing the
920i
internal fiber-optic interface.
WARNING!
HIGH VOLTAGE
DI
S
CONNECT POWER BEFORE
S
ERVICING
GREEN (GND)
RED (+6V)
POWER
S
UPPLY
J8
TAP AND RUN
CONNECTORS
GREEN (GND)
RED (+6V)
V2
V1
J4
J3
TAP AND RUN
CONNECTORS
FIBER-OPTIC
INTERFACE
POWER
S
UPPLY
J8