![Rice Lake iQube 920i Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/rice-lake/iqube-920i/iqube-920i_installation-manual_1453911015.webp)
12
iQUBE
Installation Manual
2.11.3
Remote Fiber-Optic Module (PN 77789)
The optional remote fiber-optic module provides optically isolated digital-to-analog (DAC) conversion of digital
data received from the
iQUBE
. The analog output from the module can be connected to the analog (load cell)
signal input of a standard weight indicator that can read 0-30mV (0-20mA) referenced to ground (see
Figure 2-10).
This option requires that the
iQUBE
be fitted with its internal fiber-optic card (see Figure 2-9 on page 11); both
voltage- and current-based DAC cards available for the remote fiber-optic module.
Figure 2-10. Remote Fiber-Optic Module
Figure 2-11 shows connector locations on the remote
fiber-optic interface.
Figure 2-11. Remote Fiber-Optic Interface, Including DAC
J3
DAC
J4
J1
J5
ANALOG
OUTPUT
POWER
IN
FIBER-OPTIC
INTERFACE
POWER
SUPPLY
AC
POWER
IN
ANALOG OUTPUT
TO INDICATOR
FIBER-OPTIC INPUT
FROM iQUBE
V1
V1A
V2A
V
2
J3
V2
V1
(BLACK)
(BLUE)
TRAN
S
MITTER
DAC
J4
J1
J5
ANALOG
OUTPUT
POWER
IN
+OUT
–OUT
GND
GND
+V
FIBER-OPTIC
INTERFACE