![Rice Lake iQube 920i Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/rice-lake/iqube-920i/iqube-920i_installation-manual_1453911046.webp)
920i
S
erial Commands
43
Command
Description
Values
SJ.SYS.NAME.
s
#
n
System name
System1
, system_name (24 characters, maximum)
SJ.SYS.PLATS.
s
#
n
System platforms
0,0,0,0
(specify platform numbers, 1–4, assigned to sytem)
or
NONE
(to clear platform list)
For system (SJ.SYS.) commands ending with “
s
#
n
”,
s
is the system number,
n
is the
920i
serial port number.
Table 8-4.
920i
iQUBE
System Serial Commands
Command
Description
Values
SJ.DIAG.ZEROREF#
n
Zero reference diagnostic enable
ON, OFF
SJ.DIAG.ZR.THRH#
n
Zero reference threshold
0.0–9.999999
SJ.DIAG.ZR.%THRH#
n
Zero reference percent threshold
0–100
SJ.DIAG.ZR.DELAY#
n
Zero reference delay
0–65535
SJ.DIAG.CELLBAL#
n
Cell balance diagnostic enable
ON, OFF
SJ.DIAG.CB.THRH#
n
Cell balance threshold
0.0–9.999999
SJ.DIAG.CB.%TOLR#
n
Cell balance percent tolerance
0–100
SJ.DIAG.CB.LOAD#
n
Cell balance load
0.0–9999999.0
SJ.DIAG.LDRIFT#
n
Load cell drift diagnostic enable
ON, OFF
SJ.DIAG.LD.LIMIT#
n
Load cell drift limit
0.0–9.999999
SJ.DIAG.LD.%LIMIT#
n
Load cell drift percent limit
0–100
SJ.DIAG.LD.TIME#
n
Load cell drift time
0–65535
SJ.DIAG.LD.LOAD#
n
Load cell drift load
0.0–9999999.0
SJ.DIAG.PKTOPK#
n
Peak-to-peak diagnostic enable
ON, OFF
SJ.DIAG.PK.LIMIT#
n
Peak-to-peak limit
0.0–9.999999
SJ.DIAG.CELLEMU#
n
Cell emulation enable
ON, OFF
SJ.DIAG.CE.TYPE#
n
Cell emulation type
AUTO1, AUTO2, MANUAL1, MANUAL2
SJ.DIAG.MOTBAND#
n
Motion band
0.0–9999999.0
For commands ending with “#
n
”,
n
is the number of the
920i
serial port to which the
iQUBE
is attached.
Table 8-5.
920i
iQUBE
Diagnostic Serial Commands