8.0
920i Serial Commands
The following section lists
920i
serial commands used to configure and control the
iQUBE
. See the
920i
Installation Manual
, PN 67887, for more information about using serial commands.
Command
Description
Values
SJ.SERIAL_NUMBER#
n
iQUBE
serial number
Read-only output
SJ.CONFIG#
n
iQUBE
primary-secondary
configuration
8/0/0/0, 4/0/0/0, 4/8/0/0, 4/4/0/0, 4/4/4/0, 4/4/4/4, 8/4/0/0, 8/4/
4/0, 8/8/0/0
SJ.SECT_TYPE#
n
Section type
PAIRED, CIRCULAR
SJ.VERSION.
s
#
n
System version
Read-only output.
s
is the system number,
n
is the
920i
serial port number.
SJ.DUMP#
n
Dump diagnostic parameters
Read-only output.
Dumps all SJ parameters for the
iQUBE
connected to port
n
.
SJ.DOWNLOAD#
n
Download to
iQUBE
Downloads configuration and resets
iQUBE
n
is the.
920i
serial port number to which the
iQUBE
is connected.
Table 8-1.
920i
iQUBE
Serial Commands
Command
Description
Values
SJ.LC.ID.
c
#
n
Load cell ID
Load Cell A1
, load_cell_ID (24 characters, maximum)
SJ.LC.SRLNUM.
c
#
n
Load cell serial number
(16 characters, maximum)
SJ.LC.CAPCTY.
c
#
n
Load cell capacity
1–500000
SJ.LC.SENS.
c
#
n
Load cell sensitivity
0.0001–9.9999 (mV/V)
SJ.LC.TRIM.
c
#
n
Load cell trim factor
0.0001–9.9999
SJ.LC.ZERO.
c
#
n
Load cell zero value
–0.5 to 45.0
For load cell (SJ.LC.) commands ending with “
c
#
n
”,
c
is the load cell number,
n
is the
920i
serial port number.
Table 8-2.
920i
iQUBE
Load Cell Serial Commands
Command
Description
Values
SJ.PLAT.NAME.
p
#
n
Platform name
Platform1
, platform_name (24 characters, maximum)
SJ.PLAT.CELLS.
p
#
n
Platform load cells
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 (s
pecify comma-separated list
of load cell numbers associated with this platform) or
NONE
(to clear load cell list)
SJ.PLAT.SIM.
p
#
n
Platform simulated cell
0,
1–16
SJ.PLAT.WVAL.
p
#
n
Platform test weight value
0.0–9999999.0
SJ.PLAT.WSPAN.
p
#
n
Platform span calibration
–0.5 to 512.0
SJ.PLAT.WLIN.V1.
p
#
n
–
SJ.PLAT.WLIN.V5.
p
#
n
Platform test weight value for
linearization points 1–5
0.0–9999999.0
SJ.PLAT.WLIN.F1.
p
#
n
–
SJ.PLAT.WLIN.F5.
p
#
n
Actual raw count value for platform
linearization points 1–5
–0.5 to 512.0
SJ.PLAT.CALTYPE.
p
#
n
Platform calibration type
NONE, FACTORY, CALMATCH, SECMATCH
SJ.PLAT.CALMULT.
p
#
n
Retrieve platform calibration data
—
For platform (SJ.PLAT.) commands ending with “
p
#
n
”,
p
is the platform number,
n
is the
920i
serial port number.
Table 8-3.
920i
iQUBE
Platform Serial Commands