Table 2-2. DC-200/300 (142) Settings
2.9.2
Configuring Spec 141 and 142 Settings Using the Spec Upload Utility
The DC-300 Utility Program includes a module called “Spec Upload”. This handy program allows you to more
easily do four useful things:
•
change one or any number of spec settings from your computer screen and then upload them to a
DC-200/300 rather than change them from the scale’s keyboard.
•
save the spec setting currently programmed in the DC-200/300 to a named file on your computer from
which they can be restored to the same DC-200/300 later or uploaded to other DC-200/300s so that their
spec settings match.
•
save spec settings optimized for a particular task, department or facility to a named file on the computer.
This complete set of spec settings can then be uploaded to a DC-200/300 whenever the scale’s use or
location changes, rather than have to go through and manually change each spec. It can also be used to
save a backup of your spec settings if you should need to send your scale to be serviced.
Return all the scale’s spec settings to the default settings by uploading the defaults from the computer to the
scale.
Note:
For information on how to install the DC-300 Utility Program on your computer, Section 8.2 on page 101 If
you have not already set up your computer and the scale to be able to communicate to each other using the
DC-200/300’s Ethernet connection, please see Section 6.1. If you are unsure of how to work with TCP/IP
connections or have difficulties, see your Network Administrator for help.
638
Display at Minus Weight
0: Minus display (DEFAULT)
1: Masked display
639
Masked Display at Minus Weight
0: Gross weight (DEFAULT)
1: Net weight
640
Overweight Masked
0: At +1D (DEFAULT)
1: At + 9D
641
Selection of Scale Starting Method
0: Auto start (DEFAULT)
1: Manual start
642
Weight Unit Convert
0: Yes (DEFAULT)
1: No
643
Gross Mode Display
0: Yes (DEFAULT)
1: No
644
Selection of Decimal Point Type
Sets whether the decimal point is displayed as a period (U.S. usage) or a comma (European, Latin
American, Asian usage)
0: Period display (DEFAULT)
1: Comma display
645
Selection of Scale Type
0: DC-300 scale
1: DC-200 scale
646
Automatic Unit Weight Clear Conditions
0: Disable (DEFAULT)
1: Over net 5D & gross 21D & weight stable
2: >=net 1D & weight stable
3: >=net 1D & quantity > 0 & weight stable
Spec
Description
All manuals and user guides at all-guides.com
all-guides.com
Содержание DIGI DC-200
Страница 2: ...All manuals and user guides at all guides com...
Страница 52: ...3 4 2 DC 300 Block Diagram Figure 3 10 DC 300 Block Diagram All manuals and user guides at all guides com...
Страница 53: ...3 4 3 DC 200 Block Diagram Figure 3 11 DC 200 Block Diagram All manuals and user guides at all guides com...