2.8
Setting Time and Date
Once you set the internal clock for the correct day and time it will continue to keep them, even when the scale is
off, using the internal battery on the main board. The procedure below can also be used to adjust the time when
moving from Standard to Daylight Savings Time or when the scale is moved to a new facility in a different time
zone.
Note:
SPEC 05 - DATE ORDER and SPEC 06 -TIME FORMAT allow you to set the format for date and time that
you prefer the scale to display. The defaults are Month/Date/Year for date and 12 hour for time. To change these
specifications, see Section 2.9.1.
1. Press the
MODE
key twice until the display shows
ITEM CODE PROGRAMMING
. The
S
annunciator,
indicating the Programming Mode, will illuminate.
2. Press the
+
(plus) or
–
(minus) keys to scroll through the programming options until you see the
PROGRAM DATE
screen. Enter the current date using the numeric keypad. For months or days from 1 to
9, enter a leading zero. (Ex. In a MM-DD-YY format, May 8, 2003 would be entered as 050803.) Press
the
REPRINT
key to store the data in temporary memory and move to the time programming mode.
3. Enter the current time using the numeric keypad. For numbers from 1 to 9, enter a leading zero. (Ex. In a
12 hour format, 3:06 pm would be entered as 0306.) If SPEC 06 - TIME FORMAT is set to a 12 hour
format, you use the
<<
and
>>
keys to toggle between AM and PM.
4. Press the
CODE
key to save the data or press the
PIECES
key followed by the
CLEAR
key to exit without
saving the data.
5. To return to the Stand-by Screen in the Operation Mode, press the
MODE
key three times.
2.9
Configuration Settings
This section presents the setup and configuration of the DC-200/300 counting scale to be used specifically by
distributors and service technicians. Configuring these specifications allow you to tailor the DC-200/300 to your
specific applications.
Setting the specifications allows you to modify the functionality of the DC-200/300. Use the tables in this section
to view the options you can modify. For example, if you want the function allowing you to print labels by
pressing the
+/-
keys as well as pressing the
REPRINT
key to work on the DC-200/300, refer to the DC-200/300
specification table and locate
SPEC 34 - PRINT WHEN PRESS +/- KEY
. The default for SPEC 34 is
0
, which
means that the
PRINT WHEN PRESS +/- KEY
function is turned off or disabled. To turn it on or enable it, change
the SPEC setting to
1
.
2.9.1
Configuring Specification 141 and 142 Settings from the Scale Keyboard
The following tables list the DC-200/300 specifications and their corresponding default values. The default
values are automatically set when the scale’s memory is set by the dealer for the country of operation.
SPEC 00 through SPEC 71 (Table 2-1) are customer specifications and use the 141 access code, while SPEC 600
through SPEC 646 (Table 2-2) are weight and measurement specifications, and use the 142 access code. In
programming specifications, the
REPRINT
and
–
(minus) keys allow you to move to the next or previous
specification without saving changes to the SPEC code you were just in.
Customer Specification (141 Settings)
1. To configure customer specifications, press and hold the
REZERO
key and enter
141
using the numeric
keypad. The first SPEC code, SPEC 0 is displayed, with
SP0: AUTO POWER SAVING
appearing in the
first line of the weight display and its current setting (ex.
00>0: Disable
) appearing in the second line.
If this is the SPEC that you want to modify, press
>>
or
<<
keys to scroll through the possible settings.
When the setting you want to store is displayed, press the
+
(plus) key to enter the change into temporary
memory and move to the next SPEC code.
2. If you want to modify a SPEC other than SPEC 00 and you know the number of that SPEC code, enter
the number of the SPEC code on the numeric keypad and press the
REPRINT
key. Otherwise, you can
All manuals and user guides at all-guides.com
Содержание DIGI DC-200
Страница 2: ...All manuals and user guides at all guides com...
Страница 52: ...3 4 2 DC 300 Block Diagram Figure 3 10 DC 300 Block Diagram All manuals and user guides at all guides com...
Страница 53: ...3 4 3 DC 200 Block Diagram Figure 3 11 DC 200 Block Diagram All manuals and user guides at all guides com...