10. Press the
REPRINT
key to enter the weight calibration setting.
11. Put a calibrated weight on the platform equal to the total capacity of the scale (Example, for a 25 lb scale,
place a 25 lb weight on the scale). Alternatively, you can enter the weight from the numeric keypad. The
weight appears in quantity window. Press the
REPRINT
key to save the calibration data.
The display confirms that the span settings for calibration of the scale are being saved
Finally the screen returns to the initial
CHANGE SPAN SWITCH
.
12. Once the span switch is turned off, the scale automatically returns to operation mode. The scale should
now be powered off and restarted for the new settings to take effect.