Weight and Measurement Specification (142 Settings)
1. Press and hold the
REZERO
key and enter
142
using the numeric keypad.
SP600
appears in weight
display and its current setting (ex.
2>2: LB
) appearing in the second line. If this is the SPEC that you
want to modify, press the
>>
or
<<
keys to scroll through the possible settings. When the setting you
want to store is displayed, press the
+
(plus) key to enter the change into temporary memory and move to
the next SPEC code.
2. If you want to modify a SPEC other than SPEC 600 and you know the number of that SPEC code, enter
the number of the SPEC code on the numeric keypad and press the
REPRINT
key. Otherwise, you can
use the
+
(plus) and
–
(minus) keys to scroll through the specifications until you find the one you want.
Then make your changes per the instructions in Step 1.
3. To change another SPEC code before exiting, repeat Steps 1 and 2.
4. To save all the changed SPEC settings currently in temporary memory and exit to the Operation Mode,
press the
CODE
key. To exit to the Operation Mode without saving the changes, press the
TARE
key.
5. Power down scale using the power switch on the back of the bottom of the scale, not the
ON/OFF
key on
the keyboard.
Power scale on to re-initialize the new specification settings.
Spec
Description
600
Scale Unit Specification
0: Gram
1: Kg
2: Lb (DEFAULT)
601
Display Resolution
0: 1/10000 (DEFAULT)
1: 1/5000
2: 1/2500)
602
Internal Count
0: 500,000
1: 1,000,000 (DEFAULT)
603
Minimum Display (Increment) for Scale A
0: 2 (DEFAULT)
1: 1
2: 5
3: 10
604
Weight Decimal Point Position for Scale A
0: 0
1: 0.0
2: 0.00
3: 0.000 (DEFAULT)
4: 0.0000