RHOTHETA User Manual RT-800
Page 73 of 192
Fig. 57 "Scan List Conditions" dialog
▪
“Time (def.)” hotkey (s. Fig. 57, position 1) defines the behavior of the “Scan List”
algorithm if the active frequency (signal level > squelch level) has been found.
If this hotkey is pressed, the default time of 30 seconds will be adopted after
confirming this setting with “OK”. The scan algorithm will stay for the default time of
30 sec on an active frequency before continuing with scanning of the next
frequencies.
▪
Pressing the hotkey “Edit Time” (s. Fig. 57, position 2) will open a dialog for editing
the time of staying on the actively received frequency before continuing with the
scan procedure.
▪
Pressing the hotkey “Signal>Sql.” hotkey (s. Fig. 57, position 3) defines the time of
staying on the actively received frequency before continuing with the scan
procedure. If this setting is confirmed, the scanning procedure will stay on the
actively received frequency as long as the signal level is higher than the squelch
level.
▪
If the hotkey “Endless” (s. Fig. 57, position 4) was pressed and confirmed with “OK”,
the scan algorithm will stay on the actively received frequency as long as the user
terminates the scan or skips the current frequency.