![Rhotheta RT-800 Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/rhotheta/rt-800/rt-800_user-manual_1452912069.webp)
RHOTHETA User Manual RT-800
Page 69 of 192
If this hotkey is pressed, the scan algorithm will stay on an active frequency as long as
the user terminates the scan mode or skips the actual frequency.
o
Pressing the hotkey “ID only” (s. Fig. 51, position 4) activates or deactivates the feature
“ID Only” (s. 6.2.2.3):
3.
“ELT/PLB”
:
The alarm is only triggered if an ELT/PLB signature is set and the
corresponding modulation has been detected. Otherwise the alarm will not be
activated.
4.
“ – “
:
An alarm is never triggered, regardless of whether the signal is modulated or
not.
The hotkey “ID only” is only visible for the following frequencies:
▪
121.5 MHz
▪
243 MHz
6.2.6 Scan List
The function “Scan List” provides a comfortable scanning feature of different frequency bands
in one scan procedure.
The scan algorithm in the full scan list mode compares “Search List” (accessible over “Edit
Scan”) and “Exclude List” (s. 6.2.4.3) and out of this comparison it generates an internal list of
frequencies which is scanned. All results (received signals) are saved in a “Result List”.
Note
To make any changes in the “Scan List” or “Exclude List” please always stop the running scan
procedure first.
Note
The “Start” and the “Stop” frequencies of one scan section to be entered (either in the search-
or in the scan-list) have to be inside one frequency band (s. Table 1 in chapter 4).
Designation of the currently active scan mode
Scan frequency (changing until a signal is detected)
Frequency and time of the last signal detection
Fig. 53 Scan List. Indication of frequencies
Note
When restarting the “Scan List” mode, there is a possibility to scan the full-range-procedure
that is given by comparison of search and exclude lists, or to scan only the result list.