RHOTHETA User Manual RT-800
Page 57 of 192
6.2.3.3 Fast Channel Scan Settings
o
To start the “Fast Channel Scan” mode select the corresponding line on the “Scan”
page and press “OK” or the hotkey “Start Scan” (s. Fig. 35, position 1).
Fig. 35 Activating the “Fast Channel Scan”
o
Pressing the hotkey “Stop Scan” (s. Fig. 35, position 2) will terminate the scan mode
and change to the bearing of the frequency, that was set before the scan mode has
been activated.
o
You can also stop the scan mode by pressing the “HOME” button on the “Bearing”
page with activated scan. After you have confirmed the special dialog (s. Fig. 36), this
mode will be terminated.
Fig. 36 Confirming of leaving the scan mode
o
Pressing the button “OK” during the time of the active reception of the signal, the
scanning mode will be deactivated, and the current frequency will become the new
main frequency.
o
Pressing the hotkey “Go to Result” (s. Fig. 35, position 3) during the fast channel scan
is currently running, will terminate the scan mode, adopt the frequency which was
found in this scan last time and change to the “Bearing” page into normal bearing
mode.
Pressing the hotkey “Go to Result” if the scan mode is not activated, will lead to the
“Bearing” page with the last result as the activated frequency.