Condensate Trap (Included in the
Exhaust T)
With an efficiency of greater than
95%, this unit will create much
condensation inside the flue tubes.
The condensate trap allows for the
controlled evacuation of the
condensation to a local drain
. (See
local codes)
Igniter and Flame Probe
Provides spark to burner and
flame rectification response to the
controller.
Main Igniter Controller
The control provides outputs for a
blower motor, high voltage spark
igniter, gas valve, and nonvolatile
storage of fault history. The
control receives inputs from
temperature probe, pressure
switches, Flue gas temperature
sensor, high temperature limit
switches and senses flame. The
control makes 9 tries of 3 attempts
(total of 27 tries) for ignition. If no
ignition, the control waits for one
hour before re-attempting ignition.
LCD Display and User
Control Panel
Color LCD with touch sensitive
overlay for user interface. Displays
tank set point temperature,
operational state, and various other
operational characteristics of the
water heater.
12
Triton
Service Manual SVC1020T ; Rev 4
80 and 100 gallon chassis
Parts
Содержание TRITON
Страница 7: ...Component Parts of the TRITON 7 Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis ...
Страница 8: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Wiring and Schematic Diagram 8 ...
Страница 9: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Connection Diagram 9 ...
Страница 14: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 14 ...
Страница 15: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 15 ...
Страница 16: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 16 ...
Страница 17: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 17 ...
Страница 20: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Sequence of Events 20 ...
Страница 21: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Sequence of Events 21 ...
Страница 46: ...4 6 Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Notes ...