Leak Guard
TM
What is LeakGuard
TM
LeakGuard is a proprietary auto shut-off system that prevents catastrophic damage and allows no
more than 24 ounces of water to escape the tank in a vacuum lock. This feature comes preinstalled
on premium models. The modes of operation are generally set to Auto, which is preferred and are
based on the hours of operation.
LeakGuard
TM
is available on premium models only. The control is programmable to allow detection
of leak to “Alarm Only” and allow the unit to continue to operate, or to “Disable” the unit and close
the automatic shut-off valve. The valve exercises itself once a month (Sunday at 1am) to ensure it is
in operation and to keep the valve from clogging up from sediments/debris. The unit WILL NOT
heat if control board can not confirm valves as OPEN.
Valve can be checked for the following error codes:
A110 and A11 – Shut-off Valve Monthly Test Close/Open Error
•
Drain the tank and remove the automatic shutoff valve. Clean any debris from inside valve body
and manually rotate the ball valve to ensure the motor is not seized up.
•
Reinstall the valve, fill the tank with water, and clear the alarm. If issue occurs again next month
then the valve is defective or we have heavy amounts of sediment in the water supply and some
form of water filtering system may need to be utilized to prevent buildup from occurring.
•
If no sediments/debris are present in the valve but alarm keeps occurring, replace the automatic
shutoff valve.
A112 – The control board is not seeing the valve as being “OPEN”.
•
Confirm the Molex connectors from valve to water heater wiring is securely connected.
•
Confirm no wires are loose/damaged in Molex connectors from valve to water heater.
•
Manually open the shutoff valve by rotating the Allen head screw on top of the valve actuator.
Clear the alarm. If the alarm persists, replace the automatic shutoff valve.
•
The control board will not allow the unit to heat water until the shut-off valve is confirmed
“OPEN”
•
The red line on the valve indicator shows if the valve is open or closed. See photo below. If the valve is open, the red line
will be straight in line with the water flow. If the valve is closed, the line will be horizontal to the water flow.
Valve Indicator
Auto Shut-off
Valve Actuator
Ball Valve
Triton
Service Manual SVC1020T ; Rev 4
80 and 100 gallon chassis
6 0
Содержание TRITON
Страница 7: ...Component Parts of the TRITON 7 Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis ...
Страница 8: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Wiring and Schematic Diagram 8 ...
Страница 9: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Connection Diagram 9 ...
Страница 14: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 14 ...
Страница 15: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 15 ...
Страница 16: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 16 ...
Страница 17: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis User Interface 17 ...
Страница 20: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Sequence of Events 20 ...
Страница 21: ...Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Sequence of Events 21 ...
Страница 46: ...4 6 Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis Notes ...
Страница 57: ...BACnet Configurations Triton Service Manual SVC1020T Rev 4 80 and 100 gallon chassis 5 7 ...