IDT SMBus Interfaces
PES24T3G2 User Manual
5 - 15
February 22, 2012
Notes
address and upper 6-bit doubleword system address, respectively. For example, use ADDRU = x00 and
ADDRL = 0x00 to access system address 0x00000 (port 0’s Vendor/Device ID register). Use ADDRU = x00
and ADDRL = 0x01 to access system address 0x00004 (port 0’s Command/Status register).
The format of the CMD field is shown in Figure 5.6 and described in Table 5.12.
Figure 5.6 CSR Register Read or Write CMD Field Format
Serial EEPROM Read or Write Operation
Table 5.12 indicates the sequence of data as it is presented on the slave SMBus following the byte
address of the Slave SMBus interface.
Bit
Field Name
Type
Description
0
BELL
Read/Write
Byte Enable Lower. When set, the byte enable for bits [7:0] of the data word
is enabled.
1
BELM
Read/Write
Byte Enable Lower Middle. When set, the byte enable for bits [15:8] of the
data word is enabled.
2
BEUM
Read/Write
Byte Enable Upper Middle. When set, the byte enable for bits [23:16] of the
data word is enabled.
3
BEUU
Read/Write
Byte Enable Upper. When set, the byte enable for bits [31:24] of the data
word is enabled.
4
OP
Read/Write
CSR Operation. This field encodes the CSR operation to be performed.
0 - CSR write
1 - CSR read
5
0
0
Reserved. Must be zero
6
RERR
Read-Only
and Clear
Read Error. This bit is set if the last CSR read SMBus transaction was not
claimed by a device. Success indicates that the transaction was claimed and
not that the operation completed without error.
7
WERR
Read-Only
and Clear
Write Error. This bit is set if the last CSR write SMBus transaction was not
claimed by a device. Success indicates that the transaction was claimed and
not that the operation completed without error.
Table 5.12 CSR Register Read or Write CMD Field Description
Byte
Position
Field
Name
Description
0
CCODE
Command Code. Slave Command Code field described in Table 5.10.
1
BYTCNT
Byte Count. The byte count field is only transmitted for block type SMBus transac-
tions. SMBus word and byte accesses to not contain this field. The byte count field
indicates the number of bytes following the byte count field when performing a write
or setting up for a read. The byte count field is also used when returning data to indi-
cate the number of following bytes (including status).
2
CMD
Command. This field contains information related to the serial EEPROM transaction
Table 5.13 Serial EEPROM Read or Write Operation Byte Sequence (Part 1 of 2)
Bit
6
Bit
7
Bit
0
Bit
1
Bit
2
Bit
3
Bit
4
Bit
5
BELL
BELM
WERR
BEUM
BEUU
OP
RERR
0
Содержание 89HPES24T3G2ZBAL
Страница 8: ...IDT PES24T3G2 User Manual 6 February 22 2012 Notes...
Страница 12: ...IDT Table of Contents PES24T3G2 User Manual iv February 22 2012 Notes...
Страница 14: ...IDT List of Tables PES24T3G2 User Manual vi February 22 2012 Notes...
Страница 16: ...IDT List of Figures PES24T3G2 User Manual viii February 22 2012 Notes...
Страница 20: ...IDT Register List PES24T3G2 User Manual xii February 22 2012 Notes...
Страница 32: ...IDT PES24T3G2 Device Overview PES24T3G2 User Manual 1 12 February 22 2012 Notes...
Страница 72: ...IDT SMBus Interfaces PES24T3G2 User Manual 5 20 February 22 2012 Notes...
Страница 76: ...IDT Power Management PES24T3G2 User Manual 6 4 February 22 2012 Notes...
Страница 156: ...IDT Configuration Registers PES24T3G2 User Manual 8 74 February 22 2012 Notes...