Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137
46/ 56
→ Lead time close
1 To warn people of a door closing, it is possible to display it in
advance with the configurable output signal
Alarm
(see
Pa-
rameter → Input/Output
).
0 = no warning, output is passive during closing
1 = no warning, output is active during closing
40 = approx. 8 seconds warning time, output is active during
closing
▪ The door closes after the set lead time. The time starts to
run after the hold-open time has expired.
▪ With
Push to actuate close
there is no lead time.
→ Alarm display
In this menu, some error messages can be adapted to special
requirements.
▪ Display for AKI/AKA/SSK, or SIO/SIS/ELS.
If the alarm output has been configured, it switches after
expiry of the set time.
→ FlowControl
Red Test limited
This function of the control module is exclusively for record
FlowControl, so that the RED test can be parameterised in the
operating mode „One-way“ to “Automatic“.
→ Disabled
X RED test is carried out when changing from „One-way“ mode
to “Automatic“.
→ Enabled
RED test is NOT performed when changing from „One-way“
mode to “Automatic“
→ Time activation
18 Triggering signals activated for a relatively long time (AKI,
AKA, SSK) are displayed with an error message.
0 = no error message
1..40 = display an error message after 5..200 seconds
→ Time safety
18 Safety signals activated for a relatively long time (SIO, SIS,
ELS) are displayed with an error message.
0 = no error message
1..40 = display an error message after 5..200 seconds
→ Collision display
Display collisions with an error message.
→ Disabled
X No error display.
→ Enabled
Collisions in opening and closing directions are displayed with
an error message.
Содержание system 20
Страница 1: ...record system 20 B8 Parameter explanations Translation of the original manual ...
Страница 48: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 48 56 ...
Страница 50: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 50 56 ...
Страница 51: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 51 56 Parameter overview STM 21 3 3 ...
Страница 52: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 52 56 ...
Страница 53: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 53 56 Parameter overview STM 21 RED 3 4 ...
Страница 54: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 54 56 ...
Страница 55: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 55 56 Parameter overview FEM 3 5 ...
Страница 56: ...Parameter overview V2 1_V2 6 3 IRA_B8_EN_2V2_REC_102 020401137 56 56 ...