Connecting a Power Storage DC and third-party inverter to the same network
You can use the inverter's integrated the S0 interface to collectively monitor a solar installation with third-party inverters.
In the case of a third-party product, an electricity meter with S0 must be installed at the inverter output. This meter is then
connected to the S0 interface of the Power Storage DC.
Excess power generated by the third-party inverters can be stored in the battery via the Power Storage DC.
If the Power Storage DC is accessed via the RCT Power APP, the generated power of the third-party inverters is displayed as
added-up value.
The total cable length must not exceed 20 m.
Commissioning / Wiring:
Use a twisted pair cable to link the third-parter inverter.