18
5.6
Additional Protective Conductor Connection
Install an additional protective conductor on the inverter case if required in the country of installation.
Fig. 5-6 Material not included in scope of supply
Procedure:
The additional protective conductor connection is located on the lower right side of the inverter enclosure.
Assemble the connection as shown in Fig. 5-6.
Connect the cable end to the equipotential bonding rail.
5.7
Connection
–
Power Switch
This section only applies when the RCT Power Switch is used with a battery system.
The RCT Power Switch in conjunction with the battery system ensures that your household
loads continue to be supplied in the event of a power failure. The Power switch disconnects
the household from the mains and the consumers are then powered by the battery.
When the mains supply is re-established, the Power Switch switches back and reconnects
the household to the mains without interruption.
Please Note: RCT Power Switch and the battery system are not an Uninterruptible Power
Supply (UPS)! It cannot act as a replacement for dedicated UPS devices that are used to
protect vital infrastructure such as servers, medical devices, etc.