System Safety: System Decommissioning
American Science and Engineering, Inc.
2-6
MINI
Z
Operator Manual 342-9000-1 Rev. B ECCN EAR99
•
Do not use a damaged or wet tablet AC adapter; close the connector cover tightly when
moisture or other foreign materials are present in the environment
2.6
System Decommissioning
Please be aware that at the end of its service life, an x-ray scanning system may contain materials and/
or components that have the potential for an environmental impact. Therefore, the system might
require special consideration for disposal.
This system may contain the following materials or components:
•
Lead (Pb) – Typically can be recycled or reused.
•
Oil
•
X-ray tube
•
Electronics, including removable Li-ion batteries that can be recycled and the tablet built-in Bridge
Li-polymer battery and clock battery that can be recycled
2.7
X-Ray Safety
The MINI Z system complies fully with radiation performance standards for open X-ray systems.
The X-ray module of the system is enclosed in a sealed, tamper-evident external housing. There are no
user-serviceable components inside, and it is a hazard if opened and voids the warranty.
WARNING
Do not reach into the beam path while X-rays are being generated.
Do not look into the two laser guide beams emitting from the scanning surface of
the scanner unit.
Please consult your local regulatory authority when disposing of your system and/
or any of its materials and components.
It is good practice to establish a program of instruction for all employees working in the area
of the X-ray scanners. These are portables and care must be taken to restrict areas where
untrained people are present. Consider restricting access, and posting warnings about
radiation safety and the proper cautions and procedures for working with instruments that
produce radiation.
It is important to the safety of the users and bystanders that users are fully aware of the
significant dangers from the misuse of X-rays. Note particularly that X-rays are fully capable
of penetrating through objects being scanned. Every organization using these types of
devices should have a strong commitment to radiation safety.