Advanced Scanning: Multiple Image Scanning (Manual Stitching)
American Science and Engineering, Inc.
7-4
MINI
Z
Operator Manual 342-9000-1 Rev. B ECCN EAR99
7.2
Multiple Image Scanning (Manual Stitching)
For scanning a wide area, the system provides the Multiple Images function, with the following char-
acteristics:
•
As many as 4 full-width scans can be included as multiple images in one scan group, locked in per-
spective together, and viewed and exported at the same time.
•
Each additional scan is automatically added after the previous scan if no previous scan in the group
has been selected.
•
If the operator taps a previous scan in the group (a blue border appears), that scan is selected for
replacement when the next scan is started.
•
After a replacement scan, to continue adding new scans, up to 4, start a new scan. It will automati-
cally be added at the last position.
•
After 4 scans have been created, any additional scan replaces the scan in the 4th position (unless
the operator selected a previous scan for replacement, as described above).
•
The individual scan images in a group can be “manually stitched;” the operator can interactively
manipulate the images to align with each other, providing broad area composite views.
•
Individual scans are initially displayed at a consistent resolution, optimal for a 6-inch per second
scanning rate.
•
After initial creation, if aspect ratio control is disabled
, individual scan images can be
zoomed and aspect ratios adjusted interactively for optimum matching between scans.
•
After initial creation, if aspect ratio control is enabled (blue background)
, individual scan
images can be stretched or compressed vertically by pinching or spreading with two fingers.
•
When all of the scans are arranged correctly, in the top corner of the Image area, tap the Lock but-
ton. This toggles freezing the arrangement.
i
ndicates the arrangement is locked, and
indicates that the arrangement is unlocked.
•
When the scans are locked
, the entire group can be panned vertically (but not sideways), by
tap-and-dragging any one of the scans upward or downward in the screen. Scans cannot be panned
individually, and aspect ratio is frozen in the vertical as well as the horizontal directions.
•
Individual scans in current groups can be rescanned (see
Section 7.2.4, Rescanning
) or replaced.
•
All image enhancements are available for Multiple Images groups.
•
Each enhancement is applied to all the scans in the same Multiple Images group.
•
There is no practical limit to the quantity of Multiple Images groups that can be created.
•
Exporting applies to the entire group. A combined image is added that includes all of the scans in
the group, aligned, proportioned, and sequenced as in the screen at the time of export (
Figure 7-5
).