Because the high voltage output of the No. 2
handgun affects the coating material atomization
and the efficiency of the application, it is impor-
tant to ensure that the electrical portion of the
system is operating correctly. This can be ac-
complished by performing a Short Circuit Cur-
rent Test (SCI). The normal SCI reading should
be between 80 to 100 microamperes (.08 to .10
milliamperes). See "Gun Output Test" in the
"Maintenance" section.
Power Supply Microampmeter
Power Supply Microampmeter
Power Supply Microampmeter
Power Supply Microampmeter
Power Supply Microampmeter
If the power supply, used with the 19372 No. 2
Handgun, is equipped with a microampmeter, it
can be used to indicate the total collective cur-
rent demand for the system (i.e., power supply,
handgun, fluid line, and paint & target distance).
Under normal operating conditions the meter
should indicate between 5 and 50 microam-
peres (.005 to .05 milliamperes). Readings out-
side the range may indicate a possible paint re-
sistance and/or target distance problem, or
component failure. See the "Troubleshooting
Guide" (Figure 11), the "Gun Output Test", or
the "Gun Short Circuit Current Test" in the
"Maintenance" section for troubleshooting pro-
cedures.
Gun Short Circuit Current
Gun Short Circuit Current
Gun Short Circuit Current
Gun Short Circuit Current
Gun Short Circuit Current
(SCI) T
(SCI) T
(SCI) T
(SCI) T
(SCI) Test
est
est
est
est
1.
Connect wire at contact brush to ground
via microampere meter.
2.
Activate gun switch.
3.
Read SCI on remote microampere
meter: SCI = 80 to 100 microamperes.
4.
If SCI is low or high, see TE-98-01,
"Paint, High Voltage & SCI Test Equip-
ment" manual for SCI test procedure us-
ing test probe (16688-02).
Figure 5: Gun Short Circuit Current Test Diagram
Figure 5: Gun Short Circuit Current Test Diagram
Figure 5: Gun Short Circuit Current Test Diagram
Figure 5: Gun Short Circuit Current Test Diagram
Figure 5: Gun Short Circuit Current Test Diagram
Содержание 19372
Страница 4: ...AH 95 02 4...
Страница 61: ...AH 95 02 4 NOTES NOTES NOTES NOTES NOTES...
Страница 62: ...AH 95 02 4 NOTES NOTES NOTES NOTES NOTES...