3.6. Ordering codes
3.6.1. Microwave units
The proper pair of Lower and Upper units should be selected when ordering the microwave link. This
is not true for ISM bands units (RAy17, RAy24). In such a case the same unit is used for both sides of
the link.
Note
- The Lower and Upper unit has to be selected from the same sub-band (i.e. from the same row
of the table).
The RAy10 ordering codes are stated here for clarity. The RAy10 User manual can be found here
3
.
Type
Licenced bands
ISM bands
10 GHz
11 GHz
17 GHz
24 GHz
A 10.30 – 10.59 GHz
A,B 10.70 – 11.70 GHz
B 10.15 – 10.65 GHz
C,D 10.50 – 10.68 GHz
Sub-bands
Lower [GHz]
Upper [GHz]
Lower [GHz]
Upper [GHz]
no sub-bands
no sub-bands
A
10.30-10.42
10.47-10.59
10.70-10.96
11.20-11.45
ordering code
RAy10-LA
RAy10-UA
RAy11-LA
RAy11-UA
RAy17
RAy24
B
10.15-10.30
10.50-10.65
10.96-11.20
11.45-11.70
ordering code
RAy10-LB
RAy10-UB
RAy11-LB
RAy11-UB
C
10.5005-10.5425 10.5915-10.6335
ordering code
RAy11-LC
RAy11-UC
D
10.5425-10.5845 10.6335-10.6755
ordering code
RAy11-LD
RAy11-UD
ver. 3.1
Frequency
range
17.10 – 17.30
GHz
24.00 – 24.25
GHz
In case of the two-port units, the “-2” label shall be connected to the end of the ordering code. Example:
•
RAy11-LA-2
•
RAy17-2
3.6.2. Feature keys
The Feature keys ordering code consists of three parts:
XXX-YYY-ZZZ
XXX - Product type, e.g. “RAy11”.
YYY - Feature key type.
The "SW" key is available now. This key unlocks the User speed to given value.
ZZZ - Feature key value. In case of User speed it states Mbps. Example:
•
RAy11-SW-100
... RAy11 user data speed max. 100 Mbps.
•
RAy17-SW-360
... RAy17 user data speed max. 360 Mbps.
3
http://www.racom.eu/eng/products/m/ray/index.html
RAy Microwave Link – © RACOM s.r.o.
24
Product
Содержание RAy11
Страница 2: ......
Страница 167: ...Appendix B Rain Zone Map 167 RACOM s r o RAy Microwave Link Rain Zone Map...