5.3.2. Fitting an external IE-PS-V01P-RJ45-FH connector
We recommend using an S/FTP 4×(2×23AWG) Cat.7 + 2×(2×24 AWG) cable for connecting the FOD
unit, as it is designed for external use. The cable contains two additional twisted pairs, 2x(2x24 AWG),
which are not used. The following images show the internal cable without these additional pairs.
a.
Use the tools from the
RAy Tool
set for fitting connectors. See Section 3.7, “Accessories”.
Fig. 5.31: Tools for fitting connectors
Fig. 5.32: IE-PI-RJ45-FH connector before
fitting
b.
Undo the nut on the connector cover and push it on to the cable. Then trim at least 20 mm of insu-
lation from the end of the cable.
Fig. 5.33: Tool for removing insulation
Fig. 5.34: Insulation removed
c.
Twist the braid forming the cable shielding together and wrap around the cable so that 2-3 loops
are next to each other at the end of the insulation.
Fig. 5.35: Twisted shielding
Fig. 5.36: Shielding wrapped around the cable