Station’s firmware version.
Firmware version
The internal real-time clock. The clock is set manually or it is synchronized
with NTP server and set for both stations.
Date, Time
Temperature inside the station.
Inside temperature [°C]
Station’s power supply voltage level.
Voltage [V]
6.2.2. Status – Radio
Radio unit type: L (Lower) or U (Upper) part of the frequency band.
Radio type
Horizontal or vertical polarization based on the physical installation. Indic-
ates the polarization of received signal. Local and Peer are indicated sep-
arately. The proper position of the cable is sideways down.
Notice for ISM connections (RAy17, RAy24): One side of the link must be
installed in vertical polarization and the other in the horizontal polarization.
Polarization
Displays the currently selected frequency table.
Frequency table
Nominal width of the channel. Both units in a link have to use the same
bandwidth.
Bandwidth [MHz]
Used channels. Both number of the channel and frequency in GHz are
listed.
TX channel [GHz]
RX channel [GHz]
Modulation type currently used for transmitting. When adaptive modulation
is enabled, the ACM letters are displayed as well as information about
TX modulation
maximum permitted modulation: “current modulation ACM / maximum mod-
ulation”
Current output power on the RF channel in dBm. If ATPC is enabled, the
ATPC letters are displayed as well as information about maximum permitted
power: “current power ATPC / maximum power”
TX power [dBm]
Current transfer capacity of radio channel for user data.
Net bitrate [Mbps]
The maximum RF channel capacity according to installed feature key.
Max. net bitrate [Mbps]
Received signal strength. If ATPC is enabled, the ATPC letters are dis-
played as well as information about threshold value for activation of power
control loop: “current RSS ATPC / threshold RSS”
RSS [dBm]
Signal to Noise Ratio. If ATPC is enabled, the ATPC letters are displayed
as well as information about threshold value for activation of power control
loop: “current SNR ATPC / threshold SNR”
SNR [dB]
Bit Error Rate registered at the receiving end. Instantaneous value.
BER [-]
Time elapsed since the current link connection has been established.
Link uptime
6.2.3. Status – Ethernet
Status of ethernet interface. Current bit rate (10 = 10BASE-T, 100 =
100BASE- TX and 1000 = 1000BASE-T) and state of duplex (FD = full
duplex, HD = half duplex).
Ethernet link mode
Status of the internal crossover of ethernet cables. (MDIX = internally
crossed pairs, MDI = direct connection, N/A means an unknown state).
MDIX
Switch blocking protection status.
Storm control
Switch Quality of Service status.
QoS
RAy Microwave Link – © RACOM s.r.o.
66