Name of new user.
Username
The group to which this user will belong.
Group
Password for this user.
New password
Repeat password.
Confirm password
If you want the user to have access using ssh protocol and identity
verification using ssh key, enter the ssh key here.
SSH key
Create a new user by clicking on the button
Apply
.
Mirror users
The button is located on the bottom bar.
For users from the group cli_super, the
Mirror users
button is active. Selecting this function will
copy all user accounts from Local station to Peer station. Existing user accounts on the Peer
station are deleted (except for the password of distributor, which is unique for each station).
6.3.6. Settings – Alarm limits
Fig. 6.16: Configuration menu Settings – Alarm limits
Diagnostic system of the link monitors the operation of the station. It generates various events as output.
There are two kinds of events: Warnings and Alarms. The event is always written to the system log
and indicated in the status bar. Some events have configurable thresholds. For each event you can
choose whether a SNMP trap should be sent if the event occurs.
List of configurable events with default thresholds:
RAy Microwave Link – © RACOM s.r.o.